Instrumentation Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/instrumentation-cables/ Providing Quality Products & Services for your Maintenance, Repairs and Operation needs Sat, 15 Jun 2024 02:13:20 +0000 en-US hourly 1 https://www.limkimhai.com.sg/wp-content/uploads/2020/09/cropped-LKH-Electric-Logo-512x512-1-32x32.png Instrumentation Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/instrumentation-cables/ 32 32 FR-XOL, CU / MGT / XLPE / OS / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/fr-xol-pairs-triads/ Fri, 31 Jan 2020 03:25:14 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-112/ Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FR-XOL, CU / MGT / XLPE / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Fire Barrier: Mica Tape (MGT)
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Orange or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387 (C, W, Z), SS299 (C, W, Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XOL, CU / MGT / XLPE / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FR-XIOL, CU / MGT / XLPE / IS / OS / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/fr-xiol-pairs-triads/ Fri, 31 Jan 2020 03:25:14 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-113/ Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened,
LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FR-XIOL, CU / MGT / XLPE / IS / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Fire Barrier: Mica Tape (MGT)
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Orange or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387 (C, W, Z), SS299 (C, W, Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XIOL, CU / MGT / XLPE / IS / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FR-XOSL, CU / MGT / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/fr-xosl-pairs-triads/ Fri, 31 Jan 2020 03:25:14 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-114/ Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FR-XOSL, CU / MGT / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Fire Barrier: Mica Tape (MGT)
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Low Smoke Zero Halogen (LSZH) Compound
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Orange or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387 (C, W, Z), SS299 (C, W, Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FR-XOSL, CU / MGT / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FR-XIOSL, CU / MGT / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/fr-xiosl-pairs-triads/ Fri, 31 Jan 2020 03:25:14 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-115/ Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FR-XIOSL, CU / MGT / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Fire Barrier: Mica Tape (MGT)
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Low Smoke Zero Halogen (LSZH) Compound
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Orange or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387 (C, W, Z), SS299 (C, W, Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FR-XIOSL, CU / MGT / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xosp-airs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-106/ XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Polyvinyl Chloride (PVC) Compound Type ST2
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xiosp-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-107/ XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded,
Galvanised Steel Wire Armoured, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Polyvinyl Chloride (PVC) Compound Type ST2
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FRT-XOL, CU / XLPE / OS / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/frt-xol-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-108/ XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FRT-XOL, CU / XLPE / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FRT-XOL, CU / XLPE / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FRT-XIOL, CU / XLPE / IS / OS / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/frt-xiol-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-109/ XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FRT-XIOL, CU / XLPE / IS / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FRT-XIOL, CU / XLPE / IS / OS / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FRT-XOSL, CU / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/frt-xosl-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-110/ XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FRT-XOSL, CU / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Low Smoke Zero Halogen (LSZH) Compound
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FRT-XOSL, CU / XLPE / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
FRT-XIOSL, CU / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS https://www.limkimhai.com.sg/product/frt-xiosl-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-111/ XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable
300 / 500V
BS EN50288-7

The post FRT-XIOSL, CU / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Low Smoke Zero Halogen (LSZH) Compound
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound
Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FRT-XIOSL, CU / XLPE / IS / OS / LSZH / SWA / LSZH, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>