XLPE Insulated Instrumentation Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/instrumentation-cables/xlpe-insulated-instrumentation-cables/ Providing Quality Products & Services for your Maintenance, Repairs and Operation needs Fri, 14 Jun 2024 09:22:06 +0000 en-US hourly 1 https://www.limkimhai.com.sg/wp-content/uploads/2020/09/cropped-LKH-Electric-Logo-512x512-1-32x32.png XLPE Insulated Instrumentation Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/instrumentation-cables/xlpe-insulated-instrumentation-cables/ 32 32 IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xosp-airs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-106/ XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Polyvinyl Chloride (PVC) Compound Type ST2
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post IN-XOSP, CU / XLPE / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xiosp-pairs-triads/ Fri, 31 Jan 2020 03:25:13 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-107/ XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded,
Galvanised Steel Wire Armoured, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Bedding: Polyvinyl Chloride (PVC) Compound Type ST2
Bedding Colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post IN-XIOSP, CU / XLPE / IS / OS / PVC / SWA / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
IN-XOP, CU / XLPE / OS / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xop-pairs-triads/ Fri, 31 Jan 2020 03:25:12 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-104/ XLPE Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XOP, CU / XLPE / OS / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post IN-XOP, CU / XLPE / OS / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>
IN-XIOP, CU / XLPE / IS / OS / PVC, PAIRS & TRIADS https://www.limkimhai.com.sg/product/in-xiop-pairs-triads/ Fri, 31 Jan 2020 03:25:12 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-105/ XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable
300 / 500V
BS EN50288-7

The post IN-XIOP, CU / XLPE / IS / OS / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular
Insulation: Cross-linked Polyethylene (XLPE) Compound
Insulation Colour:
Pair/s – Black/White with Black numberings
Triad/s – Red/Black/White with Black numberings
Cores Twisted: Cores twisted to form a pair, triad or quad
Wrap Film: Polyester Binder Tape
Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)
Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core
Wrap Film: Polyester Binder Tape
Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)
Outer Sheath: Flame Retardancy Polyvinyl Chloride (PVC) Compound Type ST2 FR
Outer Sheath Colour: Black or Blue

ELECTRICAL CHARACTERISTICS

Operating voltage, U0/U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 2kV for 1 minutes

REFERENCE STANDARDS

Design Specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3

INSTALLATION REFERENCE

Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post IN-XIOP, CU / XLPE / IS / OS / PVC, PAIRS & TRIADS appeared first on Lim Kim Hai Electric.

]]>