Low Voltage Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/low-voltage-cables/ Providing Quality Products & Services for your Maintenance, Repairs and Operation needs Fri, 14 Jun 2024 09:21:52 +0000 en-US hourly 1 https://www.limkimhai.com.sg/wp-content/uploads/2020/09/cropped-LKH-Electric-Logo-512x512-1-32x32.png Low Voltage Cables - Lim Kim Hai Electric https://www.limkimhai.com.sg/product-category/low-voltage-cables/ 32 32 FR-XH, CU / MGT / XLPE / LSZH – 2-5 Cores https://www.limkimhai.com.sg/product/fr-xh-2-5-cores/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-102/ Mica Taped, XLPE Insulated, LSZH Sheathed
600/1000V Cable
Compliant With IEC60502-1

The post FR-XH, CU / MGT / XLPE / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular, compacted or sectored
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyethylene (XLPE) compound
Insulation colour:
2 cores: Brown, Blue
3 cores: Brown, Black, Grey or Brown, Blue, Green/Yellow
4 cores: Brown, Black, Grey, Blue
5 cores: Brown, Black, Grey, Blue, Green/Yellow or White with Black numbering
Assembly: Cores cabled together with filler and bound with binder tape
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XH, CU / MGT / XLPE / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>
FR-XH, CU / MGT / XLPE / LSZH – Multi-Core https://www.limkimhai.com.sg/product/fr-xh-multi-core/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-103/ Mica Taped, XLPE Insulated, LSZH Sheathed
600/1000V Cable
Compliant With IEC60502-1

The post FR-XH, CU / MGT / XLPE / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2, Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation:Cross-Linked Polyethylene (XLPE) compound
Insulation colour:
2 cores: Brown, Blue
3 cores: Brown, Black, Grey or Brown, Blue, Green/Yellow
4 cores: Brown, Black, Grey, Blue
5 cores: Brown, Black, Grey, Blue, Green/Yellow or White with Black numberings
6 cores and above: White with Black numberings
Assembly: Cores cabled together and bound with binder tape
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage U0 / U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test voltage: 2kV for 1 minute

REFERENCE STANDARDS
Design specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XH, CU / MGT / XLPE / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>
FR-XAH, CU / MGT / XLPE / LSZH / AWA / LSZH – Single Core https://www.limkimhai.com.sg/product/fr-xah-single-core/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-104/ Mica Taped, XLPE Insulated, LSZH Bedded, Aluminium Wire Armoured, LSZH Sheathed
600/1000V Cable
Compliant With IEC60502-1

The post FR-XAH, CU / MGT / XLPE / LSZH / AWA / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyethylene (XLPE) compound
Insulation colour: Natural
Bedding: Low-Smoke Zero-Halogen (LSZH) compound
Bedding colour: Black
Armour: Aluminium Wire Armoured (AWA)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XAH, CU / MGT / XLPE / LSZH / AWA / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>
FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – 2-5 Cores https://www.limkimhai.com.sg/product/fr-xsh-2-5-cores/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-105/ Mica Taped, XLPE Insulated, LSZH Bedded, Galvanized Steel Wire Armoured, LSZH Sheathed
600/1000V Cable
Compliant With BS7846

The post FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular, compacted or sectored
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyethylene (XLPE) compound
Insulation colour:
2 cores: Brown, Blue
3 cores: Brown, Black, Grey or Brown, Blue, Green/Yellow
4 cores: Brown, Black, Grey, Blue
5 cores: Brown, Black, Grey, Blue, Green/Yellow or White with Black numbering
Assembly: Cores cabled together with filler and bound with binder tape
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>
FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – Multi-Core https://www.limkimhai.com.sg/product/fr-xsh-multi-core/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-106/ Mica Taped, XLPE Insulated, LSZH Bedded, Galvanized Steel Wire Armoured, LSZH Sheathed
600/1000V Cable
Compliant With BS7846

The post FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation: Cross-Linked Polyethylene (XLPE) compound
Insulation colour: White with Black numbering or Others
Assembly: Cores cabled together with filler and bound with binder tape
Bedding: Low-Smoke Zero-Halogen (LSZH) compound
Bedding colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath color: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage U0 / U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: BS7846
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 10 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FR-XSH, CU / MGT / XLPE / LSZH / SWA / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>
FR-XL, CU / MGT / XLPE / LSZH – Multi-Core https://www.limkimhai.com.sg/product/fr-xl-multi-core/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-107/ Mica Taped, XLPE Insulated, LSZH Sheathed
300/500V Cable
Compliant With BS EN50288-7

The post FR-XL, CU / MGT / XLPE / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyethylene (XLPE) compound
Insulation colour: White with Black numbering or Others
Assembly: Cores cabled together with filler and bound with binder tape
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XL, CU / MGT / XLPE / LSZH – Multi-Core appeared first on Lim Kim Hai Electric.

]]>
FR-XOL, CU / MGT / XLPE / OS / LSZH – Single Pair https://www.limkimhai.com.sg/product/fr-xol-single-pair/ Wed, 22 Jan 2020 04:30:51 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-108/ Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed
300/500V Cable
Compliant With BS EN50288-7
CONSTRUCTION

The post FR-XOL, CU / MGT / XLPE / OS / LSZH – Single Pair appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 stranded circular
Fire Barrier: Mica tape (MGT)
Insulation: Cross-linked Polyethylene (XLPE) compound
Insulation colour: Black, White or Others
Lay up: Pair – Cores twisted to pair
Wrap film: Polyester binder tape
Overall screen: Aluminium/Polyester tape, with a tinned copper drain wire 0.5mm² (7/0.3mm²) (OS)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage U0 / U: 300/500V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test voltage: 2kV for 1 minute

REFERENCE STANDARDS
Design specification: BS EN50288-7
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C,W,Z), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XOL, CU / MGT / XLPE / OS / LSZH – Single Pair appeared first on Lim Kim Hai Electric.

]]>
FR-H 110, CU / MGT / LSZH – Single Core https://www.limkimhai.com.sg/product/fr-h-110-single-core/ Wed, 22 Jan 2020 04:30:50 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-100/ Mica Taped, Cross-Linked Polyolefin LSZH Insulated, Non-Sheathed
450/750V (600/1000V*) Cable
Compliant With BS EN50525-3-41

The post FR-H 110, CU / MGT / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyolefin (LSZH) Low-Smoke Zero-Halogen compound
Insulation colour: Orange or Others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 450/750V (600/1000V*)
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: BS EN50525-3-41
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-H 110, CU / MGT / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>
FR-XH, CU / MGT / XLPE / LSZH – Single Core https://www.limkimhai.com.sg/product/fr-xh-single-core/ Wed, 22 Jan 2020 04:30:50 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-101/ Mica Taped, XLPE Insulated, LSZH Sheathed
600/1000V Cable
Compliant With IEC60502-1

The post FR-XH, CU / MGT / XLPE / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2 Stranded circular or compacted
Fire barrier: Mica tape (MGT)
Insulation: Cross-link Polyethylene (XLPE) compound
Insulation colour: Natural
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Orange or others

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire resistance: BS6387 (C,W,Z), SS299 (C), IEC60331
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 50N/mm²

The post FR-XH, CU / MGT / XLPE / LSZH – Single Core appeared first on Lim Kim Hai Electric.

]]>
FRT-XSH, CU / XLPE / LSZH / SWA / LSZH – 2-5 Cores https://www.limkimhai.com.sg/product/frt-xsh-2-5-cores/ Wed, 22 Jan 2020 04:03:57 +0000 https://www.limkimhai.com.sg/product/import-placeholder-for-105/ XLPE Insulated, LSZH Bedded, Galvanized Steel Wire Armoured, LSZH Sheathed
600/1000V Cable
Compliant With BS6724

The post FRT-XSH, CU / XLPE / LSZH / SWA / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>

CONSTRUCTION
Conductor: Plain annealed copper, Class 2, Stranded circular, compacted or sectored
Insulation: Cross-linked Polyethylene (XLPE) compound
Insulation colour:
2 cores: Brown, Blue
3 cores: Brown, Black, Grey or Brown, Blue, Green/Yellow
4 cores: Brown, Black, Grey, Blue
5 cores: Brown, Black, Grey, Blue, Green/Yellow or White with black numbering
Assembly: Cores cabled together with filler and bound with binder tape
Bedding: Low-Smoke Zero-Halogen (LSZH) compound
Bedding colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Black

ELECTRICAL CHARACTERISTICS
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes

REFERENCE STANDARDS
Design specification: BS6724
Conductor: IEC60228, BS EN60228
Flame retardancy: IEC60332-3-22, BS EN60332-3-22
Low-Smoke Zero-Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN60754-1, BS EN60754-2

INSTALLATION REFERENCE
Minimum bending radius (mm): 8 x cable overall diameter
Maximum pulling tension: 70N/mm²

The post FRT-XSH, CU / XLPE / LSZH / SWA / LSZH – 2-5 Cores appeared first on Lim Kim Hai Electric.

]]>